Centrifuges fun Idanwo Acid Nucleic ti Coronavirus COVID-19

Akoko: 2022-01-24 Deba: 193

As the outbreak pneumonia that caused by coronavirus COVID-19 has spread across continents, more and more people begin to worry that the epidemic would upgrade into a pandemic. Scientists and doctors are working together internationally to study further about this new coronavirus and trying to develop the vaccine as soon as possible.

For laboratory diagnosis, centrifuge is one of the essential equipments in laboratory nucleic acid testing of coronavirus COVID-19. As a manufacturer and enterprise of lab centrifuge, we have the responsibility to give our efforts to fight against this disease. Currently we have 3 models suitable for the clinical and diagnostic laboratory.

Model 1: TGL-20MB
Centrifuge ti o ni iyara to gaju
Max. Speed: 20000r/min
O pọju. RCF: 27800xg
Max. Capacity: 4x100ml
Temperature range: -20oC to 40 oC,
Accuracy: ±2 oC
Timer range: 1min~99min59sec
Motor: Converter motor
Ariwo: <55db
Screen: LCD color screen
Acceleration / Deceleration rates: 1--10
Power: AC220V, 50/60Hz, 18A
Iwuwo Apapọ: 70kg
Iwọn: 620x500x350mm (LxWxH)

1-1

Iyipo:
Angle Rotor 24x1.5ml, 16000rpm, 23800xg
With aerosol-tight lid

16

Model 2: XZ-20T
Ga iyara Centrifuge
Max. Speed: 20000r/min
O pọju. RCF: 27800xg
Max. Capacity: 4x100ml
Timer range: 1min~99min59sec
Motor: Converter motor
Ariwo: <55db
Screen: LCD color screen
Acceleration / Deceleration rates: 1--10
Power: AC220V, 50/60Hz, 5A
Iwuwo Apapọ: 27kg
Iwọn: 390x300x320mm (LxWxH)

1-3

Iyipo:
Angle Rotor 24x1.5ml, 16000rpm, 23800xg
With aerosol-tight lid

未 标题 -6

Model 3:  TD5B
Low Speed ​​Centrifuge
Max. Speed: 5000r/min  
O pọju. RCF: 4760xg
Max. Capacity: 4x250ml
Timer range: 1min~99min59sec
Motor: Converter motor
Ariwo: <55db
Screen: LCD color screen
Acceleration / Deceleration rates: 1--10
Power: AC220V, 50/60Hz, 5A
Iwuwo Apapọ: 35kg
Iwọn: 570x460x360mm (LxWxH)

1-7

Iyipo:
Swing Rotor 48x 5ml, 4000rpm, 2980xg
including a (stainless steal) rotor arm and 4 (aluminum alloy) rectangular buckets
For blood collection tubes (vacutainers) 5ml(13x100mm)
With aerosol-tight lid

1-8

1-9


Swing Rotor 48x 2ml, 4000rpm, 2625xg
including a (stainless steal) rotor arm and 4 (aluminum alloy) rectangular buckets
For blood collection tubes (vacutainers) 2ml(13x75mm)
With aerosol-tight lid

1-10

1-11

The above 3 models and rotors are more needed than often due to the increasingly huge needs from laboratory diagnosis on coronavirus COVID-19. Xiangzhi company is trying the best to ensure the production and supply for these models. And on the order hand we consider the biosafety as prior thing for lab workers, we highly appreciate the advices and suggestions of improving our centrifuge designs that’s able to protect lab workers better.

Lastly, please be aware of the following points when handling with hazard hazardous Material in laboratory:
Working in clinical diagnostic laboratories usually means working with potentially infectious samples like blood or other bodily fluids. But handling infectious microorganisms or harmful chemicals is quite common in research laboratories as well. To ensure the safety of laboratory personnel and to prevent laboratory acquired infections (LAIs) or other health hazards, reasonable precautions must be taken throughout the whole workflow.

Centrifuge jẹ ọkan orisun ti aerosols. Awọn iṣẹ ṣiṣe lọpọlọpọ - pẹlu kikun awọn tubes centrifuge, yiyọ awọn fila tabi awọn ideri lati awọn tubes lẹhin centrifugation, ati yiyọ omi ti o ga julọ ati lẹhinna awọn pellets ti o tun pada - le ja si itusilẹ ti awọn aerosols sinu agbegbe yàrá yàrá.
Thus, aerosol-tight lid or biocontainment cover is essential for centrifuging hazardous samples, such as blood collection tubes (vacutainers)

Aerosol-tight lids do not prevent formation of aerosols during centrifugation; rather, they ensure aerosols cannot leak from the closed system.
Ti tube fọ tabi jo, ma ṣe ṣii centrifuge fun o kere ju ọgbọn iṣẹju lẹhin ṣiṣe. Niwọn igba ti eyi ko le rii nigbagbogbo ṣaaju ki o to ṣii awọn buckets tabi rotor (aiṣedeede lojiji le jẹ ami akọkọ ti fifọ tube), a ṣeduro nduro o kere ju iṣẹju mẹwa 30 ni gbogbo igba ṣaaju ki o to ṣii awọn apoti.
Paapaa, o yẹ ki o gbe ati gbe awọn buckets tabi rotor sinu minisita biosafety (paapaa ni virology ati mycobacteriology) lati dinku eewu ti sa awọn aerosols.